3 resultados para based assay

em Helda - Digital Repository of University of Helsinki


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A randomised and population-based screening design with new technologies has been applied to the organised cervical cancer screening programme in Finland. In this experiment the women invited to routine five-yearly screening are individually randomised to be screened with automation-assisted cytology, human papillomavirus (HPV) test or conventional cytology. By using the randomised design, the ultimate aim is to assess and compare the long-term outcomes of the different screening regimens. The primary aim of the current study was to evaluate, based on the material collected during the implementation phase of the Finnish randomised screening experiment, the cross-sectional performance and validity of automation-assisted cytology (Papnet system) and primary HPV DNA testing (Hybrid Capture II assay for 13 oncogenic HPV types) within service screening, in comparison to conventional cytology. The parameters of interest were test positivity rate, histological detection rate, relative sensitivity, relative specificity and positive predictive value. Also, the effect of variation in performance by screening laboratory on age-adjusted cervical cancer incidence was assessed. Based on the cross-sectional results, almost no differences were observed in the performance of conventional and automation-assisted screening. Instead, primary HPV screening found 58% (95% confidence interval 19-109%) more cervical lesions than conventional screening. However, this was mainly due to overrepresentation of mild- and moderate-grade lesions and, thus, is likely to result in overtreatment since a great deal of these lesions would never progress to invasive cancer. Primary screening with an HPV DNA test alone caused substantial loss in specificity in comparison to cytological screening. With the use of cytology triage test, the specificity of HPV screening improved close to the level of conventional cytology. The specificity of primary HPV screening was also increased by increasing the test positivity cutoff from the level recommended for clinical use, but the increase was more modest than the one gained with the use of cytology triage. The performance of the cervical cancer screening programme varied widely between the screening laboratories, but the variation in overall programme effectiveness between respective populations was more marginal from the very beginning of the organised screening activity. Thus, conclusive interpretations on the quality or success of screening should not be based on performance parameters only. In the evaluation of cervical cancer screening the outcome should be selected as closely as possible to the true measure of programme effectiveness, which is the number of invasive cervical cancers and subsequent deaths prevented in the target population. The evaluation of benefits and adverse effects of each new suggested screening technology should be performed before the technology becomes an accepted routine in the existing screening programme. At best, the evaluation is performed randomised, within the population and screening programme in question, which makes the results directly applicable to routine use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The first line medication for mild to moderate Alzheimer s disease (AD) is based on cholinesterase inhibitors which prolong the effect of the neurotransmitter acetylcholine in cholinergic nerve synapses which relieves the symptoms of the disease. Implications of cholinesterases involvement in disease modifying processes has increased interest in this research area. The drug discovery and development process is a long and expensive process that takes on average 13.5 years and costs approximately 0.9 billion US dollars. Drug attritions in the clinical phases are common due to several reasons, e.g., poor bioavailability of compounds leading to low efficacy or toxic effects. Thus, improvements in the early drug discovery process are needed to create highly potent non-toxic compounds with predicted drug-like properties. Nature has been a good source for the discovery of new medicines accounting for around half of the new drugs approved to market during the last three decades. These compounds are direct isolates from the nature, their synthetic derivatives or natural mimics. Synthetic chemistry is an alternative way to produce compounds for drug discovery purposes. Both sources have pros and cons. The screening of new bioactive compounds in vitro is based on assaying compound libraries against targets. Assay set-up has to be adapted and validated for each screen to produce high quality data. Depending on the size of the library, miniaturization and automation are often requirements to reduce solvent and compound amounts and fasten the process. In this contribution, natural extract, natural pure compound and synthetic compound libraries were assessed as sources for new bioactive compounds. The libraries were screened primarily for acetylcholinesterase inhibitory effect and secondarily for butyrylcholinesterase inhibitory effect. To be able to screen the libraries, two assays were evaluated as screening tools and adapted to be compatible with special features of each library. The assays were validated to create high quality data. Cholinesterase inhibitors with various potencies and selectivity were found in natural product and synthetic compound libraries which indicates that the two sources complement each other. It is acknowledged that natural compounds differ structurally from compounds in synthetic compound libraries which further support the view of complementation especially if a high diversity of structures is the criterion for selection of compounds in a library.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human sport doping control analysis is a complex and challenging task for anti-doping laboratories. The List of Prohibited Substances and Methods, updated annually by World Anti-Doping Agency (WADA), consists of hundreds of chemically and pharmacologically different low and high molecular weight compounds. This poses a considerable challenge for laboratories to analyze for them all in a limited amount of time from a limited sample aliquot. The continuous expansion of the Prohibited List obliges laboratories to keep their analytical methods updated and to research new available methodologies. In this thesis, an accurate mass-based analysis employing liquid chromatography - time-of-flight mass spectrometry (LC-TOFMS) was developed and validated to improve the power of doping control analysis. New analytical methods were developed utilizing the high mass accuracy and high information content obtained by TOFMS to generate comprehensive and generic screening procedures. The suitability of LC-TOFMS for comprehensive screening was demonstrated for the first time in the field with mass accuracies better than 1 mDa. Further attention was given to generic sample preparation, an essential part of screening analysis, to rationalize the whole work flow and minimize the need for several separate sample preparation methods. Utilizing both positive and negative ionization allowed the detection of almost 200 prohibited substances. Automatic data processing produced a Microsoft Excel based report highlighting the entries fulfilling the criteria of the reverse data base search (retention time (RT), mass accuracy, isotope match). The quantitative performance of LC-TOFMS was demonstrated with morphine, codeine and their intact glucuronide conjugates. After a straightforward sample preparation the compounds were analyzed directly without the need for hydrolysis, solvent transfer, evaporation or reconstitution. The hydrophilic interaction technique (HILIC) provided good chromatographic separation, which was critical for the morphine glucuronide isomers. A wide linear range (50-5000 ng/ml) with good precision (RSD<10%) and accuracy (±10%) was obtained, showing comparable or better performance to other methods used. In-source collision-induced dissociation (ISCID) allowed confirmation analysis with three diagnostic ions with a median mass accuracy of 1.08 mDa and repeatable ion ratios fulfilling WADA s identification criteria. The suitability of LC-TOFMS for screening of high molecular weight doping agents was demonstrated with plasma volume expanders (PVE), namely dextran and hydroxyethylstarch (HES). Specificity of the assay was improved, since interfering matrix compounds were removed by size exclusion chromatography (SEC). ISCID produced three characteristic ions with an excellent mean mass accuracy of 0.82 mDa at physiological concentration levels. In summary, by combining TOFMS with a proper sample preparation and chromatographic separation, the technique can be utilized extensively in doping control laboratories for comprehensive screening of chemically different low and high molecular weight compounds, for quantification of threshold substances and even for confirmation. LC-TOFMS rationalized the work flow in doping control laboratories by simplifying the screening scheme, expediting reporting and minimizing the analysis costs. Therefore LC-TOFMS can be exploited widely in doping control, and the need for several separate analysis techniques is reduced.